What size wire for 50 amp breaker - Jan 24, 2567 BE ... Any conventional AC welder with 50 amps grading requires 230 Volts of current as function. You can use 8 AWG copper wires or 6 AWG aluminum wire ...

 
However, still, the breaker is also limited by the load; e.g. a Level 2 Chevy Volt charger needs a 40A breaker. The reason is the 125% derate required for EVSEs and other continuous loads. You must provision 125% of the actual current draw. That is why the Volt Level 2 charger is 32A. 125% of 32A is 40A, a common breaker size.. Natalie nunn leaks

As you can see, the best wire size for a 50-amp welder is 6 AWG copper or aluminum wire. But, depending on the building code, potential voltage drops, material, duty cycle, and ambient temperature. So, it is always best to consult an electrician right size wire for 50 amps. Mark, a certified electrician, simplifies electrical work.Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit.What size breaker for 24,000 BTU mini split? A 25 amp circuit breaker is the correct size for a 24,000 BTU mini split. Using a 30-amp breaker is fine too. Should I Use A 10/2 Or 10/3 Wire For A 220v Mini Split? Definitely use 10/3 – and this should also have a ground wire (“10/3 w/ground”).Line Losses (kWh) = [ (Current)^2 x (Wire Length x Constant Resistance x Charging Time)]/1,000,000. Let’s consider a case of a 50 amp charger with 6 AWG wires. The resistance constant for a 6 AWG wire is 1.296 m Ω/m. The length of the charger is 8 meters, and it takes 6 hours to fully charge.It is going to be a 3PH/460/50HP motor and PF700 75HP VFD. Problem is in the A-B book it calls for 100A breaker min for 75HP VFD. So I assume I will need not #4 AWG wire to VFD but instead #3. But that is recommended minimum. Per NEC, for 50HP (65FLA) motor, I calculate 81.25 for wire size, (#4) Fuse 113.75 (125A semiconductor) …Feb 8, 2024 · The best 70 amp wire size is 4 AWG copper wire, supporting up to 85 amps, or 2 AWG aluminum wire, handling up to 90 amps, ensuring safe and efficient power delivery for runs up to 100 feet. 1 Understanding the significance of selecting the right wire size for your 70 amp circuit breaker is crucial. The same goes for longer distances. They’re fairly straightforward to calculate since we’re using 100A as the adjusted wire size for 80 amp breaker. 100A x 140% = 140A. 100A x 160% = 160A. Confirm the wire recommendations by …Feb 4, 2024 · A 30-amp single-pole and double-pole breakers require a minimum of 10-gauge wire. A 40-amp circuit double-pole breaker requires a minimum of 8-gauge wire. A 60-amp double-pole breaker requires a minimum of 6-gauge wire. These minimum 30 amp wire size chart are safe for the current level flowing through the conductor. Dec 23, 2010 · At 230 VAC single phase 5.95 KW calls for a good 10 gauge wire. However the book for that machine recommends a 35 or 50 amp slow blow fuse. 50 amp if the plug is already on it. Don't use wire of a lower rating than the fuse... which will be more than 10 depending on the insulation of the wire. Usually 8 for 40 amps and 6 for 60 amps. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ...Where it gets a bit more difficult is at 125 amp service 50 feet, 100 feet, 150 feet, 200 feet, and up to 500 feet away. ... (100A ampacity) as a 125 amp breaker wire sizes. Now, the 1 AWG copper and 2/0 AWG aluminum wires are the standard 125 amp wires we use for long distances. However, if we have a service that is 50+ feet away from the ...Jul 16, 2564 BE ... From https://www.justanswer.com/ythi JustAnswer Customer from North Richland Hills, Texas: What size wire is needed to hook up a 50 amp ...Min. Ampacity (150W) = 12.5A × 1.25 = 15.63A. That means we need a wire size with an ampacity of 15.63A or higher. To choose the correct AWG wire size for a 12-volt circuit, consult the complete AWG wire size chart here. From this chart, we see that 18 AWG wire has an ampacity of 14A (copper wire, at average 75°C).There is a minimum wire size (gauge) that should be used for each circuit amperage rating, as defined by the circuit breaker or fuse that regulates the circuit. For 50-Amps over a distance of 150 feet, wire size for copper should be of 6 AWG, and for aluminum it is 4 AWG. When doing regular electrical repairs, double-check that the circuit ...White (or neutral wire) goes directly below it, on the silver screw (or terminal). Here is a wiring process: Step #1. Preparation. Get your wiring accessories out! One 50 amp outlet (or NEMA 14-50R), a wire (#6 or six-gauge is highly recommended), and a weather-resistant box. Also, take out your installation tools.The wattage of a 50 gallon water heater is 4500-5000 watts. That means that the circuit breaker must be able to handle at least 5625-5000 watts, or a 20 amp circuit breaker can handle at least 45000-50000 watts. Now, …2. Choose the right wire size: A 50 amp breaker requires a specific wire size to handle the higher amperage. In general, a #6 or #8 AWG cable is commonly used for 50 amp …For 50 amps, you could use 4 AWG wire with 85A ampacity (a bit of overkill but it’s OK), but you can never use 8 AWG wire with 50A ampacity (you will fry the circuit). In most cases, 6 AWG is an almost perfectly-sized wire for a 50 amp breaker. Recommended gauge wire for a NEMA 14-50 outlet. NEMA 14-50 wiring requires a specific wire for the 50 amp 240V circuits. The wiring is generally used for dryer outlets, RVs, and other high-powered appliances. If you use a NEMA 14-50 outlet, you need a 6 to 8-gauge copper wire for wiring. You may also use a 10-gauge and a 4-gauge …Bullet size is measured in calibers, but how are wires and nails measured? Learn about bullet size and caliber in this article. Advertisement All three of these questions have to d...Lets say you have a 125 Amp circuit and because of the length you end up with 2/0 copper wire. The 125 amp circuit breaker lugs are not big enough to accommodate wire that large. ... No, it's a 125 Amp max circuit with a 125 Amp breaker. The normal conductor size for that would be a #2 THHN so that is the size I would be reducing to.Learn what size of wire you need to run to your shed or barn. Our guide provides helpful information to ensure you have safe and efficient electrical wiring. Expert Advice On Impro...Use a wire stripper to remove a 1/2-inch of insulation from the white neutral wire. Insert the end of the neutral wire into an open terminal on the neutral bus bar and tighten the screw. Make sure you put only one wire under each open terminal. Strip away a 1/2-inch of insulation from the black hot wire.How do you wire a 50 amp RV plug to a breaker box? To wire a 50 amp RV plug to a breaker box, you will need a 50 amp RV receptacle, a 50 amp double-pole breaker, appropriate gauge wire, and some basic electrical tools. Turn off the power to the breaker box. What size breaker do I need for a 50 amp RV plug? The size breaker …In general, a 50 amp breaker requires a wire size of at least 6 AWG (American Wire Gauge) for copper conductors or 4 AWG for aluminum conductors. However, the specific …For a 50-amp circuit breaker, 8 AWG copper or 6 AWG aluminium is recommended. Make sure all wiring is free from defects and that you are following local building codes. [2] Here is a chart of the recommended wire size for …A 50-amp breaker uses four wires, two of which are hot feeds of 120 volts. This results in 50 amps at 120 volts for each leg. Voltage is the measurement of differences in electric ...What Size Wire Do I Need For Breaker? (15 to 50 Amps Wire Gauge Table) Robyn Toner | Licensed Electrician Updated On 09/16/2022 No Comments Are …Aug 29, 2022 · A typical electric dryer draws 30 amps and must be wired with 10-gauge cable, while an electric range or hot tub, which draw 50 amps each, must be wired with 8-gauge copper wire. Some energy-efficient home air systems draw only 40 amps and can also be wired with 8-gauge cable, while less-efficient ones may draw 60 amps and call for 6-gauge cable. Locate an electrician who can help install your generator. 2. Check if the power outlet box is accessible – most power outlet boxes are mounted on roofs. 3. Follow the electrician’s instructions to install the breaker panel. 4. Use Racking screws (12-24) to attach the breaker panel to the box using 3/8″ bolts (6).In most cases, you will need an #8 AWG wire for a 30 amp 240V circuit. The key for 30 amp wire sizing is to account for 2 NEC codes, namely: NEC 220-2 Code. This requires that a conduit wire’s maximum load (30 amps) represents 80% of …Jan 3, 2565 BE ... In this video we talk about circuit breaker and wire size. Having the proper size circuit breaker is important. The wire size must match up ...This is a 120V, 20 Amp line. Due to length, 4 AWG is called for to hold voltage drop within 3%. The panel where the circuit will originate is a Siemens G2040. It appears that the 15A and 20A circuit breakers for this panel only accept a maximum size of 6 AWG. Is it safe to run a short 2 to 4 ft length of 6 AWG wire and connect that to the 4 AWG ...In most cases, you will need an #8 AWG wire for a 30 amp 240V circuit. The key for 30 amp wire sizing is to account for 2 NEC codes, namely: NEC 220-2 Code. This requires that a conduit wire’s maximum load (30 amps) represents 80% of …Breaker sizes larger than 50A must be hardwired directly to the EVSE. A neutral wire is not required unless feeding a NEMA 14-50 receptacle, then it must be included. A 100A circuit is included for reference, future EV’s (such as F150 Lightning) may include an 80 amp charger requiring this circuit.However, still, the breaker is also limited by the load; e.g. a Level 2 Chevy Volt charger needs a 40A breaker. The reason is the 125% derate required for EVSEs and other continuous loads. You must provision 125% of the actual current draw. That is why the Volt Level 2 charger is 32A. 125% of 32A is 40A, a common breaker size.For 50 amps, you could use 4 AWG wire with 85A ampacity (a bit of overkill but it’s OK), but you can never use 8 AWG wire with 50A ampacity (you will fry the circuit). In most …Dec 7, 2562 BE ... ... 50 Amp outlet for an electric oven, Range. The cable is pulled from the kitchen o the electrical panel and installing the 50 Amp circuit breaker ...The actual wire diameter of #14 copper wire can vary among manufacturers and wire types. The wire size table below gives the typical diameter of #14 copper wire as 0.073- .064 / 1.84-1.63 inches / mm. [Thanks to Anonymous for careful editing]7) Step-by-step Guide to Wiring a 50 Amp RV Outlet. 7.1) IMPORTANT NOTES: 7.2) Turn Off Power to Main Breaker. 7.3) Locate or Install a Double-Pole Circuit Breaker. 7.4) Run 4- Conductor Wire Through Conduit. 7.5) Strip Wire Insulation. 7.6) Connect Wires to the Home Electrical Panel.Oct 2, 2023 · The Correct Wire Sizes for a 50A Sub Panel. According to the size chart recommendations from the 2002 edition of the NEC, the minimum wire for 50 amps should be 6 AWG for copper. For aluminum, it should at least be 4 AWG. However, these answers assume that there’s no voltage drop to consider. The NEC considers a 5% voltage drop as the maximum ... Apr 23, 2023 · The normal wire size for a 50 amp circuit breaker is 6 AWG copper wire. If you are using aluminum wire, it will require a 4 gauge wire size. Using the wrong wire size may affect the safety of your electrical system. Wire sizing is one of the skill that differentiates real electricians from quacks. Armatures may use a 30 amp or 60 amp wire for ... Jul 1, 2564 BE ... 240V 50A outlet and breaker wiring and install for your larger welders. I'll show you what parts to buy, how to properly wire and ground ...What Size Wire Do I Need For Breaker? (15 to 50 Amps Wire Gauge Table) Robyn Toner | Licensed Electrician Updated On 09/16/2022 No Comments Are …The answer is yes, it is suitable. For a 240V 15 Amp wire size, 10 gauge wire is suitable. However, it is expensive. This gauge is thicker than the 12 gauge wire size, and it will be hard to wire up a 15 amp outlet. The use of 10 gauge wire size occurs when the installed outlet is too far from the circuit breaker with a distance of more than 70 ...120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, ...The appropriate wire size for a 50-amp breaker is 6 AWG for copper wires and 4 AWG for aluminum wires. Using the current capacity more than the breaker amperage size will cause overheating. Even more, causing damage to the wires or surrounding components. Other Factors to Consider . The wire gauge is the primary …Nov 12, 2561 BE ... Since the 6-50 plug is rated at 50 amps, you should use a 50 amp breaker in case anything rated at 50 amps is plugged into it. 2 Likes.Viewed 11k times. 1. My house has a 10 gauge wire leading to a 50 amp breaker. My understanding is this is not allowed and the conversation should end there. However, this circuit is for the AC unit which specifies a minimum circuit amps of 33 amp and a maximum breaker of 50 amp. HVAC folks are telling me the 10 gauge wire is fine …Jun 20, 2565 BE ... Anything breaker sizing times your amps by 1.25. So 50 amps ... So 60 amp breaker is fine but your wire conductor must follow the NEC chart.What size wire for 100 amp breakerChart breaker amps waterheatertimer conduit single What size wire for 50 amp breakerWhat size wire for a 60 amp breaker?. 100 amp breaker wire size chart greenbushfarm comAmerican wire gauge "awg" chart 30 amp breaker wire size(110v,120v,240v,single & 2 poleWhat size wire for 20 amp 220v …The wiring feeding the subpanel must match or exceed the rated circuit breaker size, not the calculated load of the subpanel. That means that if the breaker is rated for 50 amps, the feeder cable wiring should be rated for 50 amps or more. However, if there is a long-distance run for theAs for wire size, you did not say what loads you want to run. Here is a calculator tool - enter your cable run (150ft) not the round trip (300ft). The breaker in your main panel is sized to protect that wire. Think about upsizing - wire or conduit is cheap, labor and digging are not. If direct burial, USE-2 or UF. If in conduit, THWN single-wire.Jan 19, 2008 · Scott_Schultz (Scott Schultz) January 19, 2008, 9:08pm 1. On inspection, a 50 amp breaker was noted to have 8 awg copper wire. This was to an outdoor jacuzzi. We know that 40 amps is the max for 8 awg AND we know there are always exceptions to these rules. 60 amp breakers are required to have 6 awg so this seems to be on the fence with the ... What Size Wire Do I Need For Breaker? (15 to 50 Amps Wire Gauge Table) Robyn Toner | Licensed Electrician Updated On 09/16/2022 No Comments Are …The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ...Jan 24, 2567 BE ... Any conventional AC welder with 50 amps grading requires 230 Volts of current as function. You can use 8 AWG copper wires or 6 AWG aluminum wire ...Jan 24, 2567 BE ... Any conventional AC welder with 50 amps grading requires 230 Volts of current as function. You can use 8 AWG copper wires or 6 AWG aluminum wire ...Jan 30, 2024 · The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A = V 3I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current. How do you wire a 50 amp RV plug to a breaker box? To wire a 50 amp RV plug to a breaker box, you will need a 50 amp RV receptacle, a 50 amp double-pole breaker, appropriate gauge wire, and some basic electrical tools. Turn off the power to the breaker box. What size breaker do I need for a 50 amp RV plug? The size breaker …for clarification, 6 GA is allowed to be connected to a 60A breaker, which will allow for a 48A EVSE. If you are installing a 50A breaker, then you would charge at 40A. This isn't the case when using ROMEX (NM-B cable). If you're using 6ga. wire in conduit, you're fine at 60A, but for Romex the limit is lower at 55A.Where it gets a bit more difficult is at 125 amp service 50 feet, 100 feet, 150 feet, 200 feet, and up to 500 feet away. ... (100A ampacity) as a 125 amp breaker wire sizes. Now, the 1 AWG copper and 2/0 AWG aluminum wires are the standard 125 amp wires we use for long distances. However, if we have a service that is 50+ feet away from the ...Pack Size, 1, Power Distribution Features, No Additional Features. Product ... This breaker as multiple wiring options to fit different power feeds and devices.The recommended wire size for a 60 amp circuit depends on factors such as voltage, distance, location, and material used. For 120V, the recommended wire size is 6 gauge copper or 4 gauge aluminum. For 240V, the recommended wire size is 4 gauge copper or 2 gauge aluminum. For 480V, the recommended wire size is 2 gauge copper …For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch …Dec 7, 2562 BE ... ... 50 Amp outlet for an electric oven, Range. The cable is pulled from the kitchen o the electrical panel and installing the 50 Amp circuit breaker ...If you apply the NEC 80% rule, 250 kcmil wire can handle up to 204 amps. That’s why it is considered a 200 amp wire. Basically, we are trying to answer what ground wire do you need for 200 amp service. If you consult the copper ground wire size chart above, you can see that you will need a 2 AWG copper ground wire to adequately ground a 250 ... Bullet size is measured in calibers, but how are wires and nails measured? Learn about bullet size and caliber in this article. Advertisement All three of these questions have to d...A 30-amp breaker does not operate safely with a 12-gauge wire. The minimum wire size that is allowable for use with a 30-amp breaker is 10 gauge. A smaller gauge of wire indicates ...Learn how to choose the right wire size and amperage rating for your electrical circuits. Find out the maximum safe carrying capacity of different wire gauges …Apr 16, 2555 BE ... I'm getting my work shop ready to do some welding and fabricating. One of the first things you need to have in a welding shop is a welder ...The Breaker Wire Size Chart is an important tool for electrical contractors and home owners alike. It provides information about the recommended AWG size for different wire sizes and conductor temperatures. Whether the wire is used in a 50-amp circuit or a 15-amp circuit, it’s important to select the correct wire size.For motors requiring a 60-amp breaker, the Minn Kota MKR-27 60-amp circuit breaker is recommended. Batteries should be stored and maintained at full charge. Failure to recharge lead-acid batteries (within 12-24 hours) is the leading cause of premature battery failure.Dec 7, 2562 BE ... ... 50 Amp outlet for an electric oven, Range. The cable is pulled from the kitchen o the electrical panel and installing the 50 Amp circuit breaker ...The Installation Procedure. After you've finished wiring your new device, which could be a 240-volt outlet for a stove or a new 50-amp RV plug, feed the wire into the panel through a knockout hole. Strip the cable, separate the wires and expose about 3/4 inch on the end of each one. Advertisement. Updated on February 8, 2024. According to the NEC, the wire size for 200 amp service is a 2/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop. For a 200-amp cable size spanning over 200 feet, choose a 500 kcmil copper wire or a 1000 kcmil aluminum wire.The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 Volts, 60°C through 90°C (140°F through 194°F), not more than three current-carrying conductors in raceway, cable, or earth (directly buried), based on ambient air temperature of 30°C (86°F). Search Amazon for your Electrical ...What is the Recommended Size Wire for a 40 Amp Breaker? The best wire size for a 40-amp breaker is 8 AWG copper or 6 AWG aluminum wire. 8 AWG wire can handle up to 50 amps and 30 amps without getting too hot. 6 AWG aluminum can handle up to 65 amps, which is more than enough for the 40 amp rating. [1]Mar 25, 2022 · Recently had an electrician install an inlet box and interlock for a portable generator. the generator in question is rated for 12,500 Peak/9,500 Running watts and has a receptacle for a 50 amp plug. After install was done, I noticed that the inlet box was only rated for 30 amps and the wiring from the inlet box to the breaker was 8-3awg with a ... For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch …

Use a wire stripper to remove a 1/2-inch of insulation from the white neutral wire. Insert the end of the neutral wire into an open terminal on the neutral bus bar and tighten the screw. Make sure you put only one wire under each open terminal. Strip away a 1/2-inch of insulation from the black hot wire. . Flights from greenville sc

what size wire for 50 amp breaker

Jan 7, 2022 · If connecting to a 50 A circuit, use a 50 A rated cord with kit. For 50 A rated cord kits, use kits that specify use with a nominal 1³⁄8" (3.5 cm) diameter connection opening. Many people don't notice that some range cords with NEMA 14-50 plugs are only rated for 40A. GE recommends a 40A cord. Nov 22, 2023 · What Size Wire for a 50 Amp Breaker? The appropriate wire size for a 50-amp breaker is 6 AWG for copper wires and 4 AWG for aluminum wires. Using the current capacity more than the breaker amperage size will cause overheating. Even more, causing damage to the wires or surrounding components. Dec 6, 2016 · 4 awg wire too large for circuit breakers. I need to run a long circuit out to a stock tank heater in a pasture. This is a 120V, 20 Amp line. Due to length, 4 AWG is called for to hold voltage drop within 3%. The panel where the circuit will originate is a Siemens G2040. It appears that the 15A and 20A circuit breakers for this panel only ... 40 amp, 50 amp, and 60 amp circuit breakers are mainly used for high-powered appliances. They are used for gas stoves, air conditioners, furnaces, etc. In these cases, having the proper wire size for each circuit breaker is necessary to prevent future electrical problems and ensure your devices’ safety.According to the wire table, #8 thhn in the 90 degree column is good for 55 amps. I understand that we only use 90 degree column for calculation purposes, but the 75 degree column doesn't list thhn , only thwn etc. which list at 50 amps. Some sources say it will take #6 thhn for 50 amps, and other sources say #8. Which is right? Thanks50 AMP Wire Size. For a maximum of 50 amps, you’ll need a wire gauge of 6. Fifty amp breakers are most often used to power many different appliances. However, a kitchen oven can alone require 50 amps. Many electric dryers also require a 50 amp breaker. Instead, there are a variety of extension cords available that are designed for RV use. 30-amp RV extension cords typically feature 10-gauge wire, and 50-amp cords usually feature 6-gauge hot and neutral wires with an 8-gauge ground. Most RV extension cords range from 10 to 50 feet long. Keep in mind, however, that the longer the extension cord ...May 15, 2561 BE ... I used 6/2 cable with 2 (black/white) 6 gauge wires and a ground wire ... (Wiring 50 Amp Breaker). Jordan Moree•20K views · 10:01 · Go to channel&...For example, don't try to install a Square D breaker in an Eaton electrical panel. Also, make sure the amperage of the breaker matches the amperage of the circuit wires and the appliance being powered. A 20-amp 240-volt circuit calls for 12-gauge wire; a 30-amp circuit calls for 10-gauge wire; a 40-amp circuit calls for 8-gauge wire; and a 50 ...May 15, 2561 BE ... I used 6/2 cable with 2 (black/white) 6 gauge wires and a ground wire ... (Wiring 50 Amp Breaker). Jordan Moree•20K views · 10:01 · Go to channel&...Line Losses (kWh) = [ (Current)^2 x (Wire Length x Constant Resistance x Charging Time)]/1,000,000. Let’s consider a case of a 50 amp charger with 6 AWG wires. The resistance constant for a 6 AWG wire is 1.296 m Ω/m. The length of the charger is 8 meters, and it takes 6 hours to fully charge.110V and 220V systems have different outlets. But the wiring is unlikely to change. 2). Amps VS Volts. Air Compressors USA has a page that shows consumers the correct wire size to use for a 220V air compressor. Their guidance is interesting because they expect readers to buy 10AWG wire for a 30A air compressor.For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch ….